Filter Results By:

Products

Applications

Manufacturers

Switching Matrix

expand availability of instrumentation I/O fulfilling test node array connections.

See Also: Switching, High Voltage Switching, Switching Matrices, Multiplexers, General Purpose Switch, Mass Interconnect


Showing results: 16 - 30 of 1666 items found.

  • PXI 12x8 Matrix, 1 Pole Switching

    40-512-021 - Pickering Interfaces Ltd.

    The 40-510 series of matrix modules feature a wide range of selectable switchingconfigurations (12x4,dual 12x4,12x8 and 24x4). Typical applications include signalrouting in ATE and data acquisition systems.Available reed relay formats are 1-pole, 2-pole and 1-Pole screened. The screenedversion is suitable for switching signals up to 50MHz. Larger matrices may be constructedby Daisy Chaining the common signals from multiple PXI modules.

  • PXI 12x4 Matrix, 2 Pole Switching

    40-510-022 - Pickering Interfaces Ltd.

    The 40-510 series of matrix modules feature a wide range of selectable switchingconfigurations (12x4,dual 12x4,12x8 and 24x4). Typical applications include signalrouting in ATE and data acquisition systems.Available reed relay formats are 1-pole, 2-pole and 1-Pole screened. The screenedversion is suitable for switching signals up to 50MHz. Larger matrices may be constructedby Daisy Chaining the common signals from multiple PXI modules.

  • PXI 12x8 Matrix, 2 Pole Switching

    40-512-022 - Pickering Interfaces Ltd.

    The 40-510 series of matrix modules feature a wide range of selectable switchingconfigurations (12x4,dual 12x4,12x8 and 24x4). Typical applications include signalrouting in ATE and data acquisition systems.Available reed relay formats are 1-pole, 2-pole and 1-Pole screened. The screenedversion is suitable for switching signals up to 50MHz. Larger matrices may be constructedby Daisy Chaining the common signals from multiple PXI modules.

  • PXI 24x4 Matrix, 2 Pole Switching

    40-513-022 - Pickering Interfaces Ltd.

    The 40-510 series of matrix modules feature a wide range of selectable switchingconfigurations (12x4,dual 12x4,12x8 and 24x4). Typical applications include signalrouting in ATE and data acquisition systems.Available reed relay formats are 1-pole, 2-pole and 1-Pole screened. The screenedversion is suitable for switching signals up to 50MHz. Larger matrices may be constructedby Daisy Chaining the common signals from multiple PXI modules.

  • Solid State Digital Matrix Switching Systems

    DX Series - Cytec Corp.

    Cytec's DX Series Switching Systems are based on solid state switch fabric. All systems are non-blocking (any input to any output) and full fan-out (any input to any or all outputs)The DX/256x256 systems are designed to switch TTL, CMOS, LVTTL, IRIG, RS232 and RS422 up to 80 Mbps NRZ. Input and output buffers are used to convert to RS422 and/or RS232 signal levels as needed.The DXM/64x64 and DXM/128x128 are modular systems capable of switching data rates to 3.2 Gbps NRZ. They are intended to switch RS422, ECL, PECL, LVDS, CML and virtually any type of digital data stream. Configurations as large as 128x128 Clock and Data systems can be easily configured.The DX/64x64 is an earlier version of the DXM and offers systems up to 64x64 with SMA connectors for ECL, PECL, LVDS or RS422.

  • PXI Single 32x8 Matrix, 1 Pole Switching

    40-531-021 - Pickering Interfaces Ltd.

    Model 40-531 very high density matrix modules are configured as a 32x8, while the 40-532 modules are configured as a Dual 16x8. Both modules are available in a choice of reed relay formats: 1-pole, 2-pole and 1-Pole screened. The screened version is suitable for switching coaxial signals up to 50MHz. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability Sputtered Ruthenium Reed Relays, offering 109 operations to give maximum switching confidence with long life and stable contact resistance.

  • PXI Dual 16x8 Matrix, 1 Pole Switching

    40-532-021 - Pickering Interfaces Ltd.

    This high-density reed relay matrix with 256 crosspoints. This model is configured as a Dual 16x8, model 40-531 is configured as a 32x8. Both modules are available in a choice of reed relay formats: 1-pole, 2-pole and 1-Pole screened. The screened version can be used for switching coaxial signals up to 50MHz. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability Sputtered Ruthenium Reed Relays, offering 109 operations to give maximum switching confidence with long life and stable contact resistance.

  • PXI Dual 16x8 Matrix, 2 Pole Switching

    40-532-022 - Pickering Interfaces Ltd.

    This high-density reed relay matrix with 256 crosspoints. This model is configured as a Dual 16x8, model 40-531 is configured as a 32x8. Both modules are available in a choice of reed relay formats: 1-pole, 2-pole and 1-Pole screened. The screened version can be used for switching coaxial signals up to 50MHz. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability Sputtered Ruthenium Reed Relays, offering 109 operations to give maximum switching confidence with long life and stable contact resistance. Larger matrices may be constructed by Daisy Chaining the common signals from multiple PXI modules. For example, seven PXI modules will form a 224x8 Matrix, a total of 1792 crosspoints in a 7-slot PXI Chassis.

  • PXI Single 32x8 Matrix, 2 Pole Switching

    40-531-022 - Pickering Interfaces Ltd.

    Model 40-531 very high density matrix modules are configured as a 32x8, while the 40-532 modules are configured as a Dual 16x8. Both modules are available in a choice of reed relay formats: 1-pole, 2-pole and 1-Pole screened. The screened version is suitable for switching coaxial signals up to 50MHz. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability Sputtered Ruthenium Reed Relays, offering 109 operations to give maximum switching confidence with long life and stable contact resistance. Larger matrices may be constructed by Daisy Chaining the common signals from multiple PXI modules. For example, seven PXI modules will form a 224x8 Matrix, a total of 1792 crosspoints in a 7-slot PXI Chassis.

  • PXI Single 24x8 Matrix, 1 Pole Switching

    40-521-021 - Pickering Interfaces Ltd.

    An ultra high density matrix module is configured as a 24x8, this range is availablein a choice of reed relay formats: 1-pole (shown here), 2-pole and 1-Pole screened. The screenedversion is suitable for switching signals up to 50MHz. Typical applications include signal routing in Functional ATE and data acquisitionsystems. These PXI matrix cards are constructed using high reliability RutheniumElectro-Plated Reed Relays, offering >10e8 operations to give maximum switchingconfidence with long life and stable contact resistance.

  • PXI Dual 12x4 Matrix, 1 Pole Switching

    40-511-021 - Pickering Interfaces Ltd.

    The 40-510 series of matrix modules feature a wide range of selectable switching configurations (12x4,dual 12x4,12x8 and 24x4). Typical applications include signal routing in ATE and data acquisition systems. Available reed relay formats are 1-pole, 2-pole and 1-Pole screened. The screened version is suitable for switching signals up to 50MHz. Larger matrices may be constructed by Daisy Chaining the common signals from multiple PXI modules.

  • PXI Single 24x8 Matrix, 2 Pole Switching

    40-521-022 - Pickering Interfaces Ltd.

    Typical applications for this high density matrix include signal routing in Functional ATE and data acquisitionsystems. These PXI matrix cards are constructed using high reliability rutheniumelectro-plated reed relays, offering >10e8 operations to give maximum switchingconfidence with long life and stable contact resistance. Larger matrices may be constructed by Daisy Chaining the common signals from multiple PXI modules. For example, 7 PXI modules will form a 168x8 Matrix, a total of 1344 crosspoints in a 7-slot PXI Chassis. All 40-521 series modules are fitted with reed relays (ruthenium sputtered type), these offer very long life with good low level switching performance and excellent contact resistance stability.Spare Reed Relays are built onto the circuit board to facilitate easy maintenance with minimum downtime.

  • PXI Dual 12x4 Matrix, 2 Pole Switching

    40-511-022 - Pickering Interfaces Ltd.

    The 40-510 series of matrix modules feature a wide range of selectable switchingconfigurations (12x4,dual 12x4,12x8 and 24x4). Typical applications include signalrouting in ATE and data acquisition systems.Available reed relay formats are 1-pole, 2-pole and 1-Pole screened. The screenedversion is suitable for switching signals up to 50MHz. Larger matrices may be constructedby Daisy Chaining the common signals from multiple PXI modules.

  • PXI Dual 12x8 Matrix, 2 Pole Switching

    40-522-022 - Pickering Interfaces Ltd.

    Medium density PXI dual 12x8, 2-pole matrix - it is also available in reed relay formats of 2-pole and 1-pole screened (see "also in this range" on right). The screened version is suitable for switching signals up to 50MHz. Typical applications include signal routing in ATE and data acquisition systems. The two banks may be used for operating a 4-wire measurement system (bank-1 for source, bank-2 for measure). Larger matrices may be constructed by daisy chaining the common signals from multiple PXI Modules.

  • PXI Single 44x4 Matrix, 2 Pole Switching

    40-523-022 - Pickering Interfaces Ltd.

    Medium density PXI dual 44x4, 2-pole matrix - it is also available in reed relay formats of 1-pole and 1-pole screened (see "also in this range" on right). The screened version is suitable for switching signals up to 50MHz. Typical applications include signal routing in ATE and data acquisition systems. The two banks may be used for operating a 4-wire measurement system (bank-1 for source, bank-2 for measure). Larger matrices may be constructed by daisy chaining the common signals from multiple PXI Modules.

Get Help